RealLine Chlamydia trachomatis Kits detect Chlamydia trachomatis plasmid and genomic DNA in clinical samples by Real-Time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection.

All components are lyophilized and ready-to use

Clear
SKU: N/A Categories: , , , Tags: ,
Description

Description

Chlamydia trachomatis is an obligate intracellular human pathogen. Infections caused by C. trachomatis are among the most common sexually transmitted infections in the world, with an estimated 50 million new cases occurring worldwide each year.

The RealLine Chlamydia trachomatis Kit detects genomic and plasmid DNA. Beside the well-kown strains of Chlamydia trachomatis, this kit is detecting the Swedish variant. This RealLine Kit is also detecting the serotypes A-C, which can effect occular trachoma in the eyes.

BIORONs RealLine Chlamydia trachomatis Kits are regularly tested by external quality assessment panels, see our Quality Assurance.

Sample Material

  • Scrapings of epithelial cells
  • Semen
  • Prostatic fluid
  • Urine

Detection channels

  • FAM (495 – 520 nm) for Internal Control (IC)
  • ROX (575 – 602 nm) for Chlamydia trachomatis DNA

For optimal results please always use the RealLine Internal Control. In case you do not use RealLine Extraction kits, order RealLine Internal Control (REF VBC8881) seperately.

Str-format

In Str-format kits the Ready-Mastermix is lyophilized and prepared in 0.2 ml white tubes arranged in a plate. For the preparation the respective number of tubes can be easily cutted.  50 µl of extracted DNA/RNA have to be pipetted to the tubes, close the tubes with PCR- foil or caps and run the test. The tubes are medium-profile tubes and fit to RealLine Cyclers, BIO-RAD cyclers and others.

Fla-format

For Fla-format 10 Tests of the lyophilized Mastermix is filled in one vial. Pipette 300 µl of the Recovery Solution into the vial, incubate at RT for 15 min and then pipette 25 µl into your tubes or plates which fit optimally to your cycler. Add 25 µl of DNA/RNA after the extraction procedure and run the program.

RealLine Cycler 48 or RealLine Cycler 96 (BIORON Diagnostics GmbH) for Str, Fla and Uni format

CFX96, iQ5 iCycler (Bio-Rad, USA) for Str, Fla and Uni format

DT96, DTLite (DNA-Technology, Russia) for Str, Fla and Uni format

Rotor-Gene® 3000, Rotor-Gene® 6000 and Rotor-Gene® Q (Qiagen, Germany) for Uni and Fla format

Eco48 (PCRMax, GB) for Fla-format

Our kits can be used with other Real-Time cyclers from ABI, Roche, Agilent etc.
Please read the IFU properly and ask us for recommendations of device settings!